ADONI TECH · ImpactCal
Industrial shock absorber · Case I8 · Rotary index table

Welding fixture index table: which shock absorber?

Index table, J = 20 kg·m², 100 N·m drive. Watch the 35-second explainer, check the calculation, then open the same example in ImpactCal and change it to your own machine.

#IndexTable#Welding#ShockAbsorber#MechanicalEngineering#MachineDesign#IndustrialAutomation#EngineeringCalculations#MakeInIndia#ImpactCal#AdoniTech

Inputs (SI units)

Inertia J20 kg·m²
Speed ω1 rad/s
Torque M100 N·m
Torque radius r0.5 m
Absorber radius R0.5 m
Cycles C120 /h

Calculation

Kinetic energyE1 = ½·J·ω² = ½·20·1²10 J
Impact velocityv = ω·R = 1·0.50.5 m/s
Drive energyE2 = (M / r)·s = (100 / 0.5)·0.0204 J
Energy per cycleE3 = E1 + E214 J
Energy per hourE4 = E3·C = 14·1201 680 J/h
Effective massme = 2·E3 / v²112 kg

s = stroke of the selected model · g = 9.81 m/s²

ImpactCal selection

AC-20-20 shock absorber
AC-20-20
Best-centred utilisation
Stroke20 mm
Stopping force875 N
Deceleration7.8 m/s²
Stopping time0.100 s
Open this example in ImpactCalSize my own application